General features:
>>Electrical Specification.
Parameter Specification
Power Supply 12~37 VDC
Power Consumption
Power down 1mA
Idle mode 50mA
GPRS class 10(Ave) 550mA
Firmware Upgrade RS232 interface
Function Setting RS232 interface
SIM card type 3V
LED Status Indicator` Yes
Serial port interface RS232 interface with DB9
connector
USSD and STK supported
SIM Application Toolkit SAT class 3, GSM 11.14
Release 97
Timer function Programmable via AT command
External antenna SMA antenna
FAX Group 3 Class 1
SMS MT, MO, CB, Text&PDU mode, by CSD and GPRS
Standards GSM07.07,GSM 07.05,GSM11.14,GSM11.11,GSM 11.10,GSM 03.38,GSM 07.10
AT Commands code GSM 07.05, 07.07
Reset Power off or AT Command
Temperature
Operating -15°C to +60°C
Storage -20°C to +70°C
Off: >70°C
Humidity Operating :<95%
Storage :<95%
>> GPRS/GSM Specification.
Parameter Specification
Frequency Dual band 900MHz/1800MHz
Output Power Class 4(2W) for EGSM 850 and 900
Class 1(1W) for GSM 1800 and 1900
Protocol support TCP/IP
GPRS Multi-slot Class 10
GPRS Mobil station Class B
Coding scheme CS1,CS2,CS3,CS4
USSD support Yes
Downlink/ Uplink max. 85.6Kbps/42.8 kbps
PBCCH support Could be supported
|
MBD-100GR is a versatile and economical platform for mobile data
transmission applications, which is based on Dual-band 900/1800/1900MHZ GSM/GPRS
communication module with TCP/IP protocol inside.
Enclosed in a solid casing for easy installation, 100GR provides reliable Real
Time data transmission anytime anywhere in the world. Benefits such as quick
transmission data, remote control, low transmission cost, better emergency
response time, enhanced fleet control, and good public relations are all
realized through the proper implementation of 100GR system.
The MBD-100GR system takes advantage of TCP/IP connection and widely mobile GPRS
/GSM network to transmit GPRS/GSM data, messages, multi-messages, file to one
point or many points.
Control Center by Packet-Switch for monitoring through either GPRS or SMS
massage system. Control
Center sets command by sending commands for monitoring through GSM system or
Internet access.
>>Main Functions
Supports Dual band 900/1800MHz operation
Remote control via SMS
Dual data communication capability through GPRS and
SMS
RS232 interface with DB9 connector for
communication
DC port with 12V~37V
One LED for power, GSM/GPRS status
>> Others
Operation system: Windows 2000sp4, XP sp2, Linux
With high circuit switched data rates,
MBD-100GR is targeted at applications that periodically need to send
or receive data remotely.
Vehicle tracing
ATM Terminals
Data Collection
Industrial and Medical Remote Monitoring Systems
Remote Diagnostics
Remote Metering
Vending/Gaming Machines
Emergency (ambulance and fire engine)
Hazardous waste management
Note: The Wireless Multi-Modem must
be mounted with at least 8 inches (20 cm) of clearance from the human body.
Data transmission: Transmission rate will be
depended on the live network
|
>>Unit Product
●Dimension: 100 mm(L) 60mm(W) 25 mm(H)
●Weight: 120g
>>Unit Package
Dimension: 200(L) 180(W) 40(H) mm
Weight: 500g
>>Unit Carton
BOX-II FOR 20 PCS
Dimension:
Weight:
|
|
|
|